top of page

Element 1.1 rehabilitated with post-extraction Prama implant immediately loaded Neck

Dr. Roberto Luongo

 

A 26-year-old patient came to my observation for a traumatic fracture of element 1.1. A prosthetically guided implant surgery is planned, taking into account the final position of the dental element, in view of a contextual orthodontic treatment with removable aligners. The tooth was extracted in an atraumatic manner and a 4.2 x 13 mm Prama RF implant inserted. At the same time, the vestibular tissue was first thickened by means of a connective graft taken from the maxillary tuberosity, after having been deprived of the epithelial component, then a particulate bone graft of porcine origin was inserted between the implant and the vestibular bone crest. Finally, a screw-retained temporary non-functional immediate loaded crown was inserted.
After 6 months, an optical impression was taken (Carestream 3600) and a final screw-retained crown made of zirconia. From the CT cone beam 1 year after the extraction, bone regeneration was evident right up to the anodized neck of Prama implant.

​

Bollino_NEW_casi_sito_prama.png
bottom of page